WAGNER AquaCoat 5010 GA 5000EAW Operating Manual page 94

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018
3
Ensure the correct
insertion position!
4
Clean and degrease the inside of the adapter.
ORDER NUMBER DOC 2369735
Valve needle assembly tool,
Order No. 2309368
3
1. Move the valve rod to the rear position so that the sealing area does
not become scratched (1).
2. Very slightly tighten valve tip (2) using an assembly tool with three
fingers.
3. Use socket or ring spanner (no wrench) to tighten the valve seat (3).
4. Slide the valve rod to the forward position (at the valve seat) (4).
B_06179
2
0.1 Nm; 0.07 lbft
SW11
1.8 Nm; 1.3 lbft
4
SW3
0.8 Nm; 0.6 lbft
1
4
B_04980
94