Safe Handling Of Wagner Spray Devices; Ground The Unit - WAGNER AquaCoat 5010 GA 5000EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018
For sufficient health and environmental safety: Operate the device in a spray booth or
on a spraying wall with the ventilation (extraction) switched on.
Wear suitable protective clothing when working with hot products.

4.2.2 SAFE HANDLING OF WAGNER SPRAY DEVICES

Hazard due to injection of lacquer or flushing agent into the skin!
The spray jet is under pressure and can cause dangerous injuries. Avoid injection of paint
or flushing agents:
Never point the spray gun at people.
Never reach into the spray jet.
Before any work on the device, in the event of work interruptions and malfunctions:
– Switch off the energy/compressed air supply.
– Relieve the pressure from the spray gun and unit.
– Secure the spray gun against actuation.
– Disconnect the control unit from the mains.
– In the event of functional faults: remedy the fault as described in the "Troubleshooting"
chapter.
If needed, the liquid ejection devices must be checked by experts (e.g., WAGNER
service technician) at least every 12 months for their work-safe condition in
accordance with DGUV regulation 100-500 Chapter 2.29 and Chapter 2.36.
– For shut down devices, the examination can be suspended until the next start-up.
In the event of skin injuries caused by lacquer or flushing agents:
Note the lacquer or flushing agent that you have been using.
Consult a doctor immediately.
Danger due to recoil forces!
Actuating the trigger can causes strong recoil forces. Thereby the user can lose his balance
and injure himself during falling.
Avoid risk of injury from recoil forces:
Ensure that you have firm footing when operating the spray gun.

4.2.3 GROUND THE UNIT

Hazard due to electrostatic charge!
Risk of injury, explosion hazard and damage to the device.
Friction, flowing liquids and air or electrostatic coating processes create charges. Flames or
sparks can form during discharge.
Correct grounding of the entire spraying system prevents electrostatic charges.
Ensure that all devices and tanks are grounded before each spraying process.
Make sure that the ground and potential equalization of all system parts are performed
reliably and continuously and can withstand the expected stress (e.g., mechanical
stress, corrosion).
Ground the work pieces to be coated.
ORDER NUMBER DOC 2369735
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020 ga 5000eaw

Table of Contents