Working; Starting The System - WAGNER AquaCoat 5010 GA 5000EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018
7.4

WORKING

Optimal coating results
– When relative humidity of 55–65% optimal coating results are expected.
– For the required electrostatic effect the work pieces to be coated must be conductive
and grounded.
– In the case of a wood coating, optimum results are achieved with a minimum of 12%
residual moisture.
Prerequisites
Ensure that:
The regular safety checks are carried out in accordance with Chapter 8.2.3,
Commissioning is carried out in accordance with Chapter 6.8.

7.4.1 STARTING THE SYSTEM

Zerstäuberluft
Mat. Druckregler
Pumpe
Atomizing air
Mat. pressure reg.
Pump
11
10
9
VM 5020WA control unit
1. Set the main switch (1) to position 1.
During the start-up phase, the device automatically performs an internal function
test and then automatically switches to recipe 1 (15).
2. Set the desired recipe.
See Chapter
7.4.6
and the following for information on how to operate the control unit.
Product supply
3. Open the compressed air supply.
4. Set pump pressure regulator (9) depending upon the paint viscosity (see operating
manual of the product pressure generator).
– DD10 pump: approx. 0.2–0.6 MPa; 2–6 bar; 30–90 psi
– DD10-/ZIP52 pump with product pressure regulator: approx. 0.3–0.6 MPa; 3–6 bar;
40–90 psi
5. DD10-/ZIP52 pump with product pressure regulator:
Set product pressure regulator (10) to approx. 0.05–0.2 MPa; 0.5–2 bar; 7–30 psi
operating pressure.
6. Set external atomizing air to approx. 0.2 - 0.4 MPa; 2 - 4 bar; 30 - 60 psi.
ORDER NUMBER DOC 2369735
15
21
22
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
POWER
0
AquaCoat
B_03371
3
1
1
B_06146
58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020 ga 5000eaw

Table of Contents