Door Adjustments And Cover Panels Fitting; Cover Plates - Access 7000 Installation Manual

Table of Contents

Advertisement

Fig. 77 Assembling the top cladding panels
Note:
For easier opening of the top/inspection panel, leave a 2 mm gap between the
top panel/inspection panel and top cladding panel.
• Use pop rivets 3.2x10 (delivered with the lift) for fixation between the full and half height top clad-
ding panels (see, Fig. 77 Assembling the top cladding panels).
• Fasten the clip list for protection against sharp edges at the end of the cut middle and side cladding
panels (see, Fig. 77 Assembling the top cladding panels).

5.10 DOOR ADJUSTMENTS AND COVER PANELS FITTING

5.10.1 COVER PLATES

• Assemble cover plates between door thresholds and filled shaft panels. Use pop rivets 3.2x10 (deliv-
ered with the lift).
7000 100 en-GB AD
ASSEMBLY
85

Advertisement

Table of Contents
loading

Table of Contents