2
The wear on the nut is checked with the gauge
provided. The gauge is placed on the lower part
of the lifting yoke. The gauge is accessible
through the inspection lid on the platform. The
gauge must be set before it is used. Check that
the value corresponds to the value on the label
– Long side of the gauge = the value on the
label
– Short side of the gauge = the value on the la-
bel minus 2 mm
3
• Push down the long side of the gauge in the
opening. When the lift is completely new
the full length of the gauge (long side), shall
go down completely to the nut on the gauge
(long side).
• Turn the screw down in position.
• Screw joint (see chapter 6.3 SPLIT MAST).
• Top fixation (see chapter 6.3.1 TOP
FIXATION).

6.4 EXTERNAL DOOR OPENER

6.4.1 HALF SIZE DOOR

1
The internal door opener is already fixated on
the half door.
Dismount the cover plate in front of the door. It
is fixated with the velcro.
2
Press the call button or destination button on
the platform to open the door.
112
Fig. 124 Control of drive nut gap
Fig. 125 Example, door opening sequence
7000 100 en-GB AD