Installing Of Heater Fan; Doors - Access 7000 Installation Manual

Table of Contents

Advertisement

OPTIONS
Fig. 113 Glue the wall panels
• When the shaft is almost completed it´s time to prepare for and build the outer roof, see chapter In-
stalling the outer roof.
• Rear Cladding panels shall be sealed with Sealing strip 64142. Attach the Sealing strip along the en-
tire panel side on each panel and build the rear wall.
Fig. 114 Rear cladding panel sealed with strip

6.2.5 INSTALLING OF HEATER FAN

The heater is installed in the lower bottom part of the lift, to the left beside the mast.
The Ventilation fans are mounted in the upper section of the shaft and ventilate the lift.
• Replace the first rear cladding panel 10 060 in the bottom of the shaft with ventilation rear panel
10122, see illustration above.
• Mount the Heater fan 44161 on the fan bracket 10179 with 2 screws.
• Mount the fan bracket 10179 with self tapping screws on the side of the mast (opposite side of the
pit prop).
• Connect the electrical socket to a suitably extern 230V-connector in the building.
• The 230V-connection should have a circuit breaker.
• Mount the Ventilation rear panel 10122.
Fig. 115 Heater, mounting

6.2.6 DOORS

The doors are mounted basically in the same way as for indoor-lifts. For outdoor lifts there are some
additions:
• Above the doors, facing outwards, a door cap (Art no 11234) be mounted.
• Brush strips shall be mounted in the door slots, this is done as described below:
106
7000 100 en-GB AD