• Put the outer roof together outside of the lift, 10116, 10117 and 10118. Start with the middle section
and tilt the side sections to connect them with the middle. Before mounting the sections, seal the
joint-ends with Sealing strip 64142 and fixate together with screw. See picture below.
• Put the complete outer roof in position and fixate it with distance 64021 and screws, use screws with
rubber gasket.
• Lift the complete outer roof (be careful, it´s heavy) in position and fixate it with distance 64021 and
screws There shall be double distance (64021) at the front/door-side.
• Put the corners 10123 (3 pieces) in position, fixate them with silicone.
The function of the open corner is to let water run of the roof.
Fig. 116 Roof panels with sealing strips 64142

6.3 SPLIT MAST

6.3.1 TOP FIXATION

Normally the lifting screw is mounted in position but if the screw is delivered separated the mounting
instructions below shall be followed:
Put the lifting screw in position and mount the parts
according to the following:
If split screw, we recommend that you put the lon-
gest part of the screw in the top of the mast.
• Pos 2 - Rubber washer
• Pos 3 - Plastic brushing
• Pos 4 - Washer
• Pos 5 - Bearing
• Pos 6 - Locking nut. The distance from the top of
the screw and down to the locking nut shall be
41mm. Tighten the two locking screws in the
locking nut (pos 6) with a force of 24 Nm.
Make sure that the locking screw are fitted with
Loctite (glue) from the factory.
• Pos 7, 8 and 9 - Belt disc, brushing and screws.
Mount the brushing pos 8 into the belt disc pos
7. Fixate the brushing pos 8 with the screw. Do
not tighten it at this moment.
• Mount the belt disc on the screw end and adjust
the level of the belt disc depending on electrical
Fig. 117 Installation of top parts