OPTIONS

6.8.3 SETTING LUBRICATION TIME

Factory default is 40% driving time. That is, oil is lubricating the screw 40% of the time. 40 % is a good
setting for normal conditions. Normal use is 20-30 rides per day with a lift installed inside. However is
the lift more frequently used or if the lift is outside in a warm or a cold climate the lubrication must be
adapted. High usage and high temperature = low settings Low usage and low temperature = high setting
Fig. 145 DIP switch setting for oil lubrication on U1 control board
DIP Switch settings
1:off2:off= 10%
1:on2:off= 20%
1:off2:on= 40%
1:on2:on= 80%

6.8.4 OIL PROTECTION COVER

After installation, the black plastic Oil protection cover needs to be checked. It shall be centred around,
and not touch, the screw.
If not, loosen the two lower nuts and adjust the cover. Before tightening the nuts, run the lift while ob-
serving the adjustment. When it´s centred, tighten the nuts. Do not tighten the nuts too hard, this can
damage the plastic cover.