6.9.1 GENERAL

Half doors are available on lifts with a travel of maximum 3 meters. For lifting platforms with travel
height up to 3 meter the door shall extend to a height of not less than 1,1 meter above the floor of the
upper landing level. For travel heights over 3 meter the door shall extend to a height of not less than
2,0 meter at each floor, including the upper landing level.

6.9.2 INSTALLATION OF HALF SIZE DOOR ON VIEW A AND C

1
Mount the half size door together with the ar-
chitrave with a door lid for the electrical cabi-
net. Make sure that the upper edge is in level.
2
Fix the door to the architraves, use at least
three pcs screw drilling 6.3x22.
3
Place the half size door together with the archi-
trave in position and open the door.
4
Locate the highest point of the floor, in the
door's opening range. Adjust the threshold of
the door to the highest point so that the door
does not get stuck or touch the floor when
opened.
5
Fixate the architrave to the inner beam of the
mast with installation screw 4.2x14.
7000 100 en-GB AD