8
Temporarily fasten one side cladding panel.
9
Tighten the second fixing pos 2/ ILLUSTRATION
165 in the floor landing.
10
Pull out the wire into the mast.

6.9.3 INSTALLATION OF HALF SIZE DOOR ON VIEW B

• Locate the highest point of the floor, in the door's opening range in view B.
• Place the architrave with a door lid for the electrical cabinet so that the upper edge is 1100 mm from
the highest point of the floor view B.
• Fixate the architrave with a door lid for the electrical cabinet with screw drilling 4,2 mm into the in-
ner beam.
• Continue the installation of shaft and doors on side A and C. See chapter 5.7 SHAFT CONSTRUCTION.
If cable channel assembly is used, seeFig. 157 Cable channel assembly, this must be considered when
building the shaft on view A and C.
• Mount the shaft profile (part no. 10 039) on view A and C up to the lower part of the threshold on
the upper level.
• The distances between door threshold and safety frame are to be 10-12 mm.
• Mount shaft panels and doors on side B up to a level, 125 mm below the top landing.
• Fixate two angle brackets into the floor landing, 47 mm down from the floor.
Fig. 151 Fix the door temporarily
Fig. 152 Side cladding panel fastening –half size door
7000 100 en-GB AD