The double hinged glass door is delivered with the the glass doors separated from the door frame.
The door frame is mounted in the shaft before installing the glass doors.

6.10.2 INSTALLATION

1
When mounting double hinged glass doors, the
outer cable channels are replaced with hidden
cable channels. The hidden cable channel is
placed in the shaft between the top of the door
frame and the mast. Calculate the level of the
hidden channel when you build the shaft
2
Remove the cover panel in the top of the door
frame. Remove the middle screw and loosen
the others. Slide the panel down.
3
Before you put the door in position, pull out
the cables from the door frames and out
through the architrave.
4
Fixate the door frame according to chapter
5.7.3 DOORS. The door frame must be straight
and follow the platform to get a flush opening.
5
Check the adjustment by opening/closing the
doors and see that the door circuit is function-
ing also when pushing the door.
6
Adjust the door contact vertically (Y) and hori-
zontally (X). Adjust the door contacts on each
glass door. Two or four contacts
7
Release the screw for adjustment and tighten
after adjustments have been made.