Resetting the Terminal

Trakker Antares 241X Handheld Terminal User's Manual
39 AGaramond
Boot Menu Options
Option
Description
Boot System
If you did remove the batteries, make sure you install a charged main
battery pack or the terminal will not turn on. Press 1 to boot the
terminal. Once the terminal is finished booting, your application
appears on the screen.
Press 2 to load the terminal firmware. To upgrade or load the
Run Loader
firmware, you should use the Firmware Upgrade option in the
TRAKKER Antares 2400 Menu System. For help, see "Upgrading the
Firmware" in Chapter 2 of the 2400 Family system manual.
Press 3 to turn off the terminal. When you turn on the terminal, the
Power Down
Boot Menu screen appears again if POST passes.
If the terminal or application is locked up, try the following steps in order:
To reset the terminal
• Scan the Boot Terminal bar code to reset the terminal.
Boot Terminal
*-.1*
*-.1*
If the terminal will not scan the Boot Terminal bar code, try a warm boot
to reset the terminal as described next.
To warm boot the terminal
1 Press _ to turn off the terminal. Press _ to turn on the terminal.
2 Use the TRAKKER Antares 2400 Menu System to reboot the terminal.
Press ( \ 2 4 8 to enter the TRAKKER Antares 2400 Menu
a
System.
Choose System Menu and then Upgrade Firmware.
b
Choose OK, then YES, then press %. The Boot Menu appears.
c
Press 1 to boot the terminal.
d
3 Scan the Reset Firmware bar code to restart the firmware and
application.
Reset Firmware
*-.*
*-.*
If the terminal or application still will not respond, perform a cold boot to
reset the terminal.