Intermec Trakker Antares 2400 User Manual page 76

Handheld terminal
Hide thumbs Also See for Trakker Antares 2400:
Table of Contents

Advertisement

Chapter 4— Troubleshooting and Maintenance
Problems While Configuring the Terminal (continued)
Problem
You see this error message when exiting the
Configuration Menu:
Commandname
command failed.
Remainder of configuration
not updated.
On a 2415, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Terminal
IP address or Controller
(Host) IP address set to an
invalid address of 0.x.x.x or
127.x.x.x. Configuration was
not updated.
On a 2415, you configure the security ID
and the changes do not appear to be saved.
You scan a configuration command, such as
Keypad Caps Lock, and you hear three low
beeps.
On a 2415, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Terminal
IP address and Default Router
address set to the same
address. Configuration was
not updated.
62
39 AGaramond
nugget
Solution
The two-character name (syntax) of the configuration command that
failed is listed on the first line of the error message.
Check the command listed in the message. To find the command,
use the "Configuration Commands by Syntax" table in Appendix A
of the 2400 Family system manual. Make sure the command is set
correctly for the options and network communications you are using
with the terminal. For help, see Chapter 6, "Configuration
Command Reference," in the 2400 Family system manual.
For example, you may see this message:
SS
command failed.
There may be a problem with the configuration due to a change
made with the Scanner Selection (SS) command.
The 2.4 GHz RF network is enabled and there is a problem with the
network configuration. You need to change the terminal IP address
and/or the controller IP address (host IP address for a TCP/IP
network). Choose Primary Network from the Communications
Menu.
The terminal IP address or the controller/host IP address is set to
0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP
address for the terminal and controller or host.
For help, see "Using RF Communications on the 2415" on page 48.
If you cannot fix the addressing problem, check with your network
administrator to get the IP address assigned to the terminal and the
Intermec Gateway or DCS 30X or the host.
You can only set the security ID with the 2.4 GHz RF network
enabled. The Network Activate command must be set to the 2.4
GHz RF network before you can save any changes to the security ID
command.
If you are working in the TRAKKER Antares 2400 Menu System,
you cannot scan configuration commands. Use the Configuration
Menu to change the terminal's configuration, or exit the menu
system to scan configuration commands.
The 2.4 GHz RF network is enabled and there is a problem with the
network configuration. You need to change the terminal IP address
and/or the default router address. Choose Primary Network or
Advanced Network from the Communications Menu.
The terminal IP address and the default router address are both set to
the same address. Set a valid IP address for the terminal and the
default router.
For help, see "Using RF Communications on the 2415" on page 48.
If you cannot fix the addressing problem, check with your network
administrator to get the IP addresses for each RF network device.
Trakker Antares 241X Handheld Terminal User's Manual

Advertisement

Table of Contents
loading

Table of Contents