Problems Transmitting Data Through the Serial Port

Problems Transmitting Data Through the Intermec Gateway or DCS 30X

Problems Transmitting Data Through the Intermec Gateway or DCS 30X

Problem
Transaction Buffer Full.
Sending Buffer Transactions.
Transaction Aborted.
Transmit Error XX, press Enter.
Receive Error XX, press Enter.
Shutting down.
Controller Shutdown.
Trakker Antares 241X Handheld Terminal User's Manual
39 AGaramond
If you are having problems sending or receiving data through the
integrated I/O port on the terminal, check these possible problems:
• Make sure the terminal is connected to the PC, host computer, or RS-
232 serial device using the appropriate cable.
• If the terminal is in a communications dock, make sure that the
communications dock is connected to the serial device using the
appropriate cable.
• Make sure the terminal's serial port parameters are configured to match
the serial port configuration on the PC, host computer, or serial device.
For help, see "Using Serial Communications on the Terminal" on page
44.
If you have a problem while running the application on the terminal in a
UDP Plus or WTP network, check these possible communications
problems.
Solution
The buffer holding transactions to be sent to the Intermec Gateway or
DCS 30X is full. Stop collecting data with this terminal. Make sure the
terminal is communicating with the Intermec Gateway or DCS 30X and let
the terminal send all the transactions in the buffer before you continue
collecting data.
This is an information message to tell you that buffered transactions are now
being sent to the Intermec Gateway or DCS 30X. You can begin collecting
data again once the message clears.
The transaction just sent to the Intermec Gateway or DCS 30X was not
received. Try sending the transaction again.
There is an error transmitting data to the Intermec Gateway or DCS 30X. XX
represents the status code error. Note the error code listed in the message and
contact your local Intermec service representative for help. Press \ to continue.
There is an error receiving data from the Intermec Gateway or DCS 30X. XX
represents the status code error. Note the error code listed in the message and
contact your local Intermec service representative for help. Press \ to continue.
The Intermec Gateway or DCS 30X is shutting down. You may continue
collecting data and buffer the transactions in the terminal until the Intermec
Gateway or DCS 30X starts again, or stop collecting data with the terminal.
The Intermec Gateway or DCS 30X has shut down. You may continue
collecting data and buffer the transactions in the terminal until the Intermec
Gateway or DCS 30X starts again, or stop collecting data with the terminal.