Problems While Operating the Terminal (continued)
Problem
The Battery LED is on and the terminal
beeps once every 15 seconds.
The terminal is booting and you see a
message that POST failed.
The terminal displays the Boot Menu.
The terminal appears to be locked up
and you cannot enter data.
You are sending and receiving information
through the network, and the terminal
appears to be operating slowly.
Trakker Antares 241X Handheld Terminal User's Manual
39 AGaramond
Solution
The battery pack charge is low. You have a few minutes of power left.
Replace the battery pack with a spare charged battery pack, or charge the
battery pack.
The screen displays the system that failed POST. Report the error
message to your supervisor.
Press % to exit the error message. The Boot Menu appears. Press 1 to
boot the terminal. Your application appears on the screen. If the terminal
still will not boot, contact your local Intermec service representative for
help.
You remove the battery pack and do not replace it within 15 minutes.
Once you replace the battery pack and turn on the terminal, the Boot
Menu appears. Press 1 to boot the terminal and continue working. For
help on the Boot Menu, see "Booting and Resetting the Terminal" on
page 71.
Try these possible solutions:
Scan a bar code label to see if the terminal responds.
Press _ to turn off the terminal. If it turns off, press _ to turn on
the terminal. You can continue working.
If the terminal will not turn off, reset the terminal. Press and hold _
for approximately 12 seconds to reset the terminal. The Good Read
LED blinks once and the terminal turns off.
Press _ to turn on the terminal. The terminal boots all the systems,
clears RAM memory, and starts the application.
Remove the battery pack. Let the terminal sit for 1 minute. Install the
battery pack. Press _ to turn on the terminal.
(2415 only) Wait at least 10 seconds and try again. If the 2415 is still
connecting to the Intermec Gateway or DCS 30X or the host, it
ignores any input from the keypad or scanner. Make sure the Connect
LED is on before continuing.
If you keep returning to the Boot Menu, try reloading the firmware.
For help, see "Upgrading the Firmware" in Chapter 2 of the 2400
Family system manual.
If the terminal will not boot or reset, contact your local Intermec
service representative for help.
The terminal may be configured for the 5x6, 6x8, or 12x16 font type.
These font type values may cause the 241X to scroll, and therefore
operate, more slowly when it displays information on the screen.
Change the font type to a value other than 5x6, 6x8, or 12x16. For
help, see "Display Font Type" or "Display Spacing" in Chapter 6 of
the 2400 Family system manual. If the terminal continues to operate
slowly, contact your local Intermec service representative for help.
Chapter 4— Troubleshooting and Maintenance
59