Intermec Trakker Antares 2400 User Manual page 77

Handheld terminal
Hide thumbs Also See for Trakker Antares 2400:
Table of Contents

Advertisement

nugget
Problems While Configuring the Terminal (continued)
Problem
On a 2415, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Terminal
IP address and Controller
(Host) IP address set to the
same address. Configuration
was not updated.
On a 2415, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Default
Router address is not on the
terminal's network.
Configuration was not
updated.
On a 2415, you scan a configuration
command to set one of these parameters and
hear three low beeps:
Controller IP Address (UDP Plus)
or Host IP Address (TCP/IP)
Terminal IP Address
Default Router
Network Activate
On the 241X with an integrated PDF417
scanner, you configure the Scanner Trigger
command to enable pulse triggering, and the
changes do not appear to be saved.
You are configuring a 241X with the clone
application and see an error message.
Trakker Antares 241X Handheld Terminal User's Manual
39 AGaramond
Solution
The 2.4 GHz RF network is enabled and there is a problem with the
network configuration. You need to change the terminal IP address
and/or the controller IP address (host IP address for a TCP/IP
network). Choose Primary Network from the Communications
Menu.
The terminal IP address and the controller/host IP address are both
set to the same address. Set a valid IP address for the terminal and
Intermec Gateway, DCS 30X, or host.
For help, see "Using RF Communications on the 2415" on page 48.
If you cannot fix the addressing problem, check with your network
administrator to get the IP address assigned to the terminal and the
controller or host.
The 2.4 GHz RF network is enabled and there is a problem with the
network configuration. You need to change the default router
address. Choose Advanced Network from the Communications
Menu.
The terminal and Intermec Gateway or DCS 30X (UDP Plus or
WTP network), or host (TCP/IP network) are on different networks,
and the terminal is not on the same network as the default router.
When the terminal is on a different IP subnetwork from the
Intermec Gateway, DCS 30X, or host, you must set the Default
Router and Subnet Mask commands. Set a valid IP address for
terminal, Intermec Gateway or DCS 30X or host, and default router.
For help, see "Using RF Communications on the 2415" on page 48.
If you cannot fix the addressing problem, check with your network
administrator to get the IP addresses for each RF network device.
If the Network Activate command is enabled (2.4 GHz RF network
enabled) and you are configuring the 2415, these IP addresses must
be valid.
To set these four parameters, follow these steps:
1
Disable the Network Activate (NA) configuration command.
2
Set the terminal IP address.
3
Set the controller IP address or the host IP address.
4
Set the default router address (if necessary).
5
Enable the Network Activate command.
You can change an IP address with the network enabled as long as it
still defines a valid network configuration.
Earlier versions of PDF417 scanners do not support pulse triggering.
For help upgrading your scanner, consult your local Intermec service
representative.
The server terminal and the client terminal may not have the same
hardware or software configuration. Make sure that both terminals
have the same hardware configuration, firmware version, and clone
application version. For help, see Chapter 2, "Configuring and
Managing the Terminals," in the 2400 Family system manual.
Chapter 4— Troubleshooting and Maintenance
63

Advertisement

Table of Contents
loading

Table of Contents