List Of Field Settings For Indoor Unit - Daikin RXQ12AHR Service Manual

Table of Contents

Advertisement

SiAF341904E
1.2

List of Field Settings for Indoor Unit

Mode
First
Description
No.
Code
(2)
No.
Filter cleaning
sign interval
0
Filter type
1
Remote controller thermistor
10 (20)
2
3
Filter cleaning sign
Remote controller thermistor
6
control during group control
7 (6)
Time for absence area detection
Dry operation time during Eco
10 (7)
mode
Low airflow setting when
11
thermostat OFF during Eco mode
Setting the rate of human
6 (6)
detection
Airflow adjustment
11 (21)
7
Compensating the temperature
8 (6)
around people
Optional accessories output
0
selection (field selection of output
for adaptor for wiring)
External ON/OFF input (Set when
1
ON/OFF is to be controlled from
outside.)
Thermostat differential
2
changeover (Set when remote
12 (22)
sensor is to be used.)
Auto restart after power failure
5
reset
Airflow setting when cooling
6
thermostat is OFF
11 (6) Compensating the floor
temperature
Ceiling height setting, Setting of
0
normal airflow
Airflow direction setting (Set when
1
a sealing material kit has been
installed)
Swing pattern settings
2 (6)
13 (23)
4
Airflow direction adjustment range
6
External static pressure settings
Setting of swing patterns when
7
cooling thermostat is OFF
13
Setting of circulation airflow
14
Circulation airflow patterns
15
Switching panel type
Part 5 Field Settings and Test Operation
Second Code No.
01
Long life filter
Approx.
10,000
Ultra long life
Approx.
filter
Light
Standard filter
Approx.
Long life filter
Remote
controller
thermistor +
Suction air
thermistor
Displayed
Not permitted
30 minutes
30 minutes
Disabled
High sensitivity
OFF
Suction air
temperature only
Indoor unit
turned ON by
thermostat
Forced OFF
1°C
Not equipped
LL tap
4°C
F (4 directions)
All direction
synchronized
swing
Disabled
Pattern 1
Standard panel
02
Approx.
5,000
hrs.
hrs.
Approx.
2,500
Heavy
1,250
hrs.
hrs.
Approx.
200
100
hrs.
hrs.
Ultra long life
filter
Only suction air
thermistor
Not displayed
Permitted
60 minutes
60 minutes
Enabled
Low sensitivity
Completion of
airflow
adjustment
Priority given on
the suction air
temperature
ON/OFF control
0.5°C
Equipped
Set fan speed
2°C
Refer to page 120.
T (3 directions)
Refer to page 122.
Refer to page 122.
Refer to page 123.
Enabled
Pattern 2
Designer panel
Field Settings for Indoor Unit
: Factory setting
03
04
Only remote
controller
thermistor
Continuous (not
90 minutes
returning to
cooling)
Infrared
Standard
presence sensor
sensitivity
disabled
Start of airflow
adjustment
Priority given on
Standard
the floor
temperature
Operation output
Error output
External
protection device
input
0°C
–2°C
W (2 directions)
Facing swing
Pattern 3
Pattern 4
111