Error code
E1 - 01
Outdoor unit PCB error
E1 - 02
Defective outdoor unit PCB
E2 - 01
Earth leakage detection error (Master)
E2 - 02
Earth leakage detection error (Slave 1)
E2 - 03
Earth leakage detection error (Slave 2)
E2 - 06
Missing of earth leakage detection core (Master)
E2 - 07
Missing of earth leakage detection core (Slave 1)
E2 - 08
Missing of earth leakage detection core (Slave 2)
E3 - 01
High pressure switch activated (Master)
E3 - 02
High pressure switch activated (Master)
E3 - 03
High pressure switch activated (Slave 1)
E3 - 04
High pressure switch activated (Slave 1)
E3 - 05
High pressure switch activated (Slave 2)
E3 - 06
High pressure switch activated (Slave 2)
E3 - 07
High pressure switch activated (Batch)
E3 - 13
Liquid stop valve check error (Master)
E3 - 14
Liquid stop valve check error (Slave 1)
E3 - 15
Liquid stop valve check error (Slave 2)
E3 - 20
High pressure switch activated (Master)
E3 - 21
High pressure switch activated (Slave 1)
E3 - 22
High pressure switch activated (Slave 2)
E4 - 01
Low pressure error (Master)
E4 - 02
Low pressure error (Slave 1)
E4 - 03
Low pressure error (Slave 2)
E5 - 01
Compressor M1C lock (Master)
E5 - 02
Compressor M1C lock (Slave 1)
E5 - 03
Compressor M1C lock (Slave 2)
E5 - 07
Compressor M2C lock (Master)
E5 - 08
Compressor M2C lock (Slave 1)
E5 - 09
Compressor M2C lock (Slave 2)
E7 - 01
Fan motor M1F lock (Master)
E7 - 02
Fan motor M2F lock (Master)
E7 - 05
Fan motor M1F instantaneous overcurrent (Master)
E7 - 06
Fan motor M2F instantaneous overcurrent (Master)
E7 - 09
Fan motor M1F IPM error (Master)
E7 - 10
Fan motor M2F IPM error (Master)
E7 - 13
Fan motor M1F lock (Slave 1)
E7 - 14
Fan motor M2F lock (Slave 1)
E7 - 17
Fan motor M1F instantaneous overcurrent (Slave 1)
E7 - 18
Fan motor M2F instantaneous overcurrent (Slave 1)
E7 - 21
Fan motor M1F IPM error (Slave 1)
E7 - 22
Fan motor M2F IPM error (Slave 1)
E7 - 25
Fan motor M1F lock (Slave 2)
E7 - 26
Fan motor M2F lock (Slave 2)
E7 - 29
Fan motor M1F instantaneous overcurrent (Slave 2)
E7 - 30
Fan motor M2F instantaneous overcurrent (Slave 2)
E7 - 33
Fan motor M1F IPM error (Slave 2)
E7 - 34
Fan motor M2F IPM error (Slave 2)
Part 6 Service Diagnosis
Description of error
Troubleshooting with Remote Controller
Troubleshooting
Refer to the E1 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the E2 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the E3 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the E4 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the E5 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the E7 flowchart and make a diagnosis
of the relevant fan motor based
on the Error code shown to the left.