Advertisement

EKEQFCBAV3-US (EEV KITS)
INSTALLATION INSTRUCTIONS
Safety Considerations
Optional kit to use in combination with Daikin condensing units
with field supplied non VRV air handler units.
Field supplied air handler units can be connected with a Daikin
condensing unit via a control box and expansion valve kit. Each
circuit or coil requires a separate control box and expansion valve
kit. This manual describes the installation of the expansion valve
kit and the installation and operation of the EKEQMCBAV3-US
control box.
The below mentioned cautions should be considered prior to
installation
Multi-module condensing units are permitted. However,
each refrigerant system cannot exceed the maximum
tonnage allowed by the applicable VRV heat pump system
type.
The automatic refrigerant charging and leak detection
function are not possible when the EKEQMCBAV3-US is
used.
The manufacturer of the outdoor unit has limited
responsibility for total performance of the system because
performance is determined by the total system. The
discharge air may fluctuate depending on selected
air handler units and depending on the installation
configuration.
Connectivity to DIII-net devices only allowed with:
- Intelligent Touch Manager
This equipment is not designed for year-round cooling
applications with low indoor humidity conditions, such as
Electronic Data Processing rooms.
Only personnel that have been trained to install, adjust, service
or repair(hereinafter, "service") the equipment specified in this
manual should service the equipment. The manufacturer will not
be responsible for any injury or property damage arising from
improper service or service procedures. If you service this unit,
you assume responsibility for any injury or property damage
which may result. In addition, in jurisdictions that require one or
more licenses to service the equipment specified in this manual,
only licensed personnel should service the equipment.
Improper installation, adjustment, servicing or repair of the
equipment specified in this manual, or attempting to install,
adjust, service or repair the equipment specified in this manual
without proper training may result in product damage, property
damage, personal injury or death.
IOD-7042D
08/2020
WARNING
© 2015 - 2016, 2020
19001 Kermier Rd., Waller, TX 77484
Only personnel that have been trained to install, adjust, service
or repair(hereinafter, "service") the equipment specified in this
manual should service the equipment. The manufacturer will not
be responsible for any injury or property damage arising from
improper service or service procedures. If you service this unit,
you assume responsibility for any injury or property damage
which may result. In addition, in jurisdictions that require one or
more licenses to service the equipment specified in this manual,
only licensed personnel should service the equipment.
Improper installation, adjustment, servicing or repair of the
equipment specified in this manual, or attempting to install,
adjust, service or repair the equipment specified in this manual
without proper training may result in product damage, property
damage, personal injury or death.
S
AFELYD ISPOSE OF ALLP ACKING ANDT RANSPORTATIONM ATERIALS
IN ACCORDANCE WITH FEDERAL
. P
ORDINANCES
WOODEN PARTSA ND PLASTICP ACKING ITEMSU SEDI NT RANSIT MAY
RESULT IN INJURY OR DEATHB YS UFFOCATION
Checking Product Received
Upon receiving the unit, inspect it for damage from shipment.
Claims for damage, either shipping or concealed, should be
filed immediately with the shipping company. Do not install this
accessory if it is determined that the integrity or safety has been
compromised by freight damage.
Check the unit model number, specifications, and electrical char-
acteristics to determine if they are correct. In the event an incor-
rect unit is shipped, it must be returned to the supplier and must
NOT be installed. The manufacturer assumes no responsibility for
installation of incorrectly shipped units.
Pre-Installation Instructions
Carefully read all instructions for the installation prior to installing
product. Make sure each step or procedure is understood and
any special considerations are taken into account before starting
installation. Assemble all tools, hardware and supplies needed to
complete the installation. Some items may need to be purchased
locally. Make sure everything needed to install the product is on
hand before starting.
www.daikincomfort.com
WARNING
PROP 65 WARNING
FOR CALIFORNIA CONSUMERS
WARNING
Cancer and Reproduc�ve Harm
www.P65Warnings.ca.gov
WARNING
,
STATEA ND LOCALL AWSO R
ACKING MATERIALSI NCLUDING NAILS
-
0140M00517-A
,
,
METAL
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EKEQFCBAV3-US and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin EKEQFCBAV3-US

  • Page 1 In addition, in jurisdictions that require one or Field supplied air handler units can be connected with a Daikin more licenses to service the equipment specified in this manual, condensing unit via a control box and expansion valve kit.
  • Page 2: Codes & Regulations

    O NOT CONNECT TO OR USE ANY DEVICE THAT IS NOT DESIGNED CONSUMER AFFAIRS CERTIFIED BY AIKIN FOR USE WITH THIS UNIT ERIOUS PROPERTY DAIKIN NORTH AMERICA LLC DAMAGE PERSONAL INJURY REDUCED UNIT PERFORMANCE AND 7401 SECURITY WAY HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OF SUCH NON...
  • Page 3: Model Identification

    Model Identification Parts Refer to this manual in combination with the instructions provided with the air handler for the correct installation procedure. The electrical characteristics of the air handler, the EEV kit and the building power supply must agree. Installation •...
  • Page 4: Before Installation

    EKEXV500-US VRV IV Range Outdoor Units Note: The header and distributor are not included when The EKEQFCBAV3-US control box can be connected to VRV IV determining the coil volume. heat pump systems only with a maximum number of 3 connect- able control boxes to 1 system.
  • Page 5: Selecting The Installation Site

    IMPORTANT NOTES: • Choose a flat and strong mounting surface. • The expansion valve is an electronic type, it is controlled by • Ambient temperature of the control box is between 14°F the thermistors that are added in the circuit. Each expansion (-10°C) and 104°F (40°C).
  • Page 6 1. Air handler unit WARNING 2. Connection pipe from expansion valve kit to air handler O AVOID POSSIBLE EXPLOSION THE LINE FROM THE NITROGEN 3. Valve kit CYLINDER MUST INCLUDE A PRESSURE REGULATOR AND A PRESSURE 4. Liquid pipe RELIEF VALVE HE PRESSURE RELIEF VALVE MUST BE SET TO OPEN AT 5.
  • Page 7: High Voltage

    IMPORTANT NOTES: 4. Remove the pipe fixing clamp (C) by unscrewing 2 x 10-32” (M5) screws. Make sure that the expansion valve is installed vertically. 5. Remove the upper and lower pipe insulations. Make sure there is enough free space for future maintenance. Figure 4 shows the required service space.
  • Page 8 Installation of the Electrical Control Box Figure 8 X24A Figure 6 4. Use a small screwdriver and follow indicated instructions for connecting cable wires into the terminal connector according to the wiring diagram. H3 H5 H5 Figure 9 WARNING HIGH VOLTAGE! ISCONNECT POWER BEFORE SERVICING ULTIPLE POWER SOURCES MAY BE PRESENT...
  • Page 9: Electrical Wiring

    5. Install the conduit fittings (field supplied) on the conduit wiring and wiring instructions. mounting plate with two PT screws (recommended torque 2. Attach the earth leakage circuit breaker and fuse to the 7.5 in-lbs.). Use only the provided PT screws (K50x10mm) power supply line.
  • Page 10 Connecting the wiring: EKEQMCBAV3-US Y1E ....Electronic expansion valve 1. Connect the wires to the terminal board according to the X1M-C1/C2 ..Output: fan ON/OFF wiring diagram, Figure 12. X1M-F1/F2 ..Communication outdoor unit See Figure 9 for wiring intake in the control box. The wiring X1M-P1/P2..Communication remote control intake hole indication H1 refers to the H1 cable of the corre- X1M-R1/R2 ..Thermistor liquid...
  • Page 11 Maximum length Description AWG/Cross section * Specifications Connect to feet (m) AWG 12 L1, L2 Power supply Power supply Power supply 230 V 1-60Hz 0.01" Y1 ~ Y6 Expansion valve Expansion valve kit 65 (20) Digital output 12 V DC (†) connection Thermistor R2T...
  • Page 12 Installation of Thermistors - Refrigerant Installation of the Thermistor Cable Thermistors 1. Put the thermistor cable in a separate protective tube. 2. Always add a pull-relief to the thermistor cable to avoid strain on the thermistor cable and loosening of the thermis- WARNING tor.
  • Page 13: Test Operation

    Test Operation 4. Put the supplied piece of rubber around the thermistor (R2T/ R3T) to avoid loosening of the thermistor after some years. After installation and once the field settings are defined, the installer is obliged to verify correct operation. Therefore a test run must be performed, refer to the installation manual of the outdoor unit.
  • Page 14: Important Note

    The combination of “Fan OFF during thermo OFF” and “Fan ON system capacity is shown in the following table. during defrost/oil return” will result in fan ON during thermo OFF. Operation Setting in Case of Power Failure This setting applies to the EKEQFCBAV3-US control box. Setting the Indoor Fan Control...
  • Page 15: Troubleshooting

    (GFCI) breaker frequently actuates, or ON/ Operation and Display Signals OFF switch does not properly work. Turn off the main power switch. For EKEQFCBAV3-US only • If the display , the unit number and the operation lamp TEST Abnormal operation on condenser flash and the malfunction code appears.
  • Page 16: Maintenance

    • Check if there are too many inhabitants in the room. Cooling effect decreases if heat gain of the room is too large. • Check if the heat source of the room is excessive. Cooling effect decreases if heat gain of the room is too large. The air handler unit is freezing up •...
  • Page 17 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 18 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 19 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 20: Customer Feedback

    CUSTOMER FEEDBACK Daikin is very interested in all product comments. Please fill out the feedback form on the following link: https://daikincomfort.com/contact-us You can also scan the QR code on the right to be directed to the feedback page. Our continuing commitment to quality products may mean a change in specifications without notice.