PV Array Layout Design
Array design is the physical layout of the Solar PV modules
and associate a cabling for modules. Array design with
Enphase IQ8D Microinverter offers flexibility. Each IQ8D
Microinverter can be connected to 2 series connected PV
modules or a single high-power module based on module
compatibility.

Information Required for Array Design

Solar module specifications.
Type of PV module – Monofacial or Bifacial, 54-
cell/108 half-cell, 60-cell/120 half-cell, 66-cell/132
half-cell and 72-cell/144 half-cell.
Available installation area of the proposed location
(including shading, pitch, orientation, roof material/
type, and access).
Total number of modules/Microinverters to be
installed.

Optimized Site Layout

Site access zones.
Setbacks from roof edges.
Shading zones.
Keep out zones for adjacent obstacles.
© 2022 Enphase Energy Inc. All rights reserved.
You can consider any array configuration, module
orientation, azimuth, and tilt angle for the PV modules.
Please note that IQ8D has a single Maximum Power
point tracking and if connected with 2 series connected
modules; both the panels should have same orientation,
azimuth, and tilt angle for maximizing power output.

Design Considerations for PV Array Layout

Site electrical configuration and layout.
Structural mounting integrity.
Site shade paths.
Load bearing capacity of the terrace, rooftop or the
structure on which the PV system is mounted.
Typical and maximum wind loads at that location, also
factoring the height of the installation.
Site access (access to arrays for maintenance, etc.).

Figure 20: Optimized Site Layout