Table 22: Enphase Iq8D Commercial Gateway Specifications - enphase IQ8D-72-E-US Design Manual

Commercial pv design guide microinverter system
Hide thumbs Also See for IQ8D-72-E-US:
Table of Contents

Advertisement

Dimensions (WxHxD)
Weight
Ambient temperature range
Environmental rating
Altitude
Production CTs
Consumption CTs
Integrated Wi-Fi
EthernetCT-600-SPLIT (order three or
six, as needed)
Mobile
Compliance
© 2022 Enphase Energy Inc. All rights reserved.
MECHANICAL AND ELECTRICAL DATA
21.3 x 12.6 x 4.5 cm (8.4" x 5" x 1.8")
-40° to 46° C (-40° to 115° F) if installed in an enclosure
IP30. For installation indoors or in an NRTL-certified, NEMA type 3R enclosure.
-Capable of measuring 400A of continuous current with 1.0% accuracy
- Accuracy of +/-0.5% for revenue grade production metering(ANSI C12.20 certified)
- Internal aperture measures 43 mm to support up to maximum size of 1000KCMIL
- Capable of measuring up to 600A continuous current with 2.5% accuracy
- Aperture of 50 * 50 mm up to a maximum size of 300KCMIL conductors
- Service entrance rated with UL2808 certification
- Rated for pollution degree 3
- Accuracy of +/-2.5% for consumption monitoring
INTERNET CONNECTION OPTIONS
802.3, Cat5E (or Cat 6) UTP Ethernet cable, not included
Optional, CELLMODEM-M1-06-SP-05 or CELLMODEM-M1-06-AT-05, not included
Compliance
47 CFR, Part 15, Class B, ICES 003
EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2

Table 22: Enphase IQ8D Commercial Gateway Specifications

17.6 oz (498 g)
-40° to 65° C (-40° to 149° F)
To 2000 meters (6,560 feet)
conductors
-UL2808 certified
802.11b/g/n
UL 916
CAN/CSA C22.2 No. 61010-1
IEC/EN 61010-1:2010,
ANSI C12.20
IQ8D-DG-MKT-00397-02-EN-US-2022-06-10