Internet Connection Options; Installing Iq8D Commercial Gateway In An Outdoor Enclosure - enphase IQ8D-72-E-US Design Manual

Commercial pv design guide microinverter system
Hide thumbs Also See for IQ8D-72-E-US:
Table of Contents

Advertisement

Internet Connection Options

The IQ8D Commercial Gateway requires a connection to the Internet for reporting to Enlighten. You can provide this
connection through an existing broadband router, other Wi-Fi access point at the installation site, or by using the Enphase
Mobile Connect cellular modem CELLMODEM-M1-06-SP-05 or CELLMODEM-M1-06-AT-05.
Method A: Integrated Wi-Fi.
Method B: Enphase Mobile Connect [order Enphase
CELLMODEM-M1-06-SP-05 or CELLMODEM-M1-06-
AT-05 separately].
Method C: Ethernet cable (not included, installer must
provide). This method requires that you use the ferrite
bead included with the IQ8D Commercial Gateway.

Installing IQ8D Commercial Gateway in an Outdoor Enclosure

The IQ8D Commercial Gateway must be installed inside of
an electrical enclosure, keeping the operating temperature
of the Gateway in mind. This enclosure must be large
enough to house the Gateway. If you use a power line
bridge or other networking component, make sure the
enclosure can accommodate a receptacle. The enclosure
can be metal or non-metallic but should be non-metallic if
Wi-Fi or cellular networks are used for the Gateway Internet
connection. The enclosure must meet the following
requirements:
Use a NEMA type 3R, 4, or better rated outdoor
enclosure with hinged cover or screw cover of suitable
dimensions. Typical enclosure dimensions are in the
range of 10" x 10" x 4" to 12" x 12" x6".
Connect the IQ8D Commercial Gateway to phases and
the neutral. A neutral is required for powering the IQ8D
Commercial Gateway and for metering. It does not
ship with a plug-in style power cord, so a receptacle
is not required in the enclosure for powering the IQ8D
Commercial Gateway.
© 2022 Enphase Energy Inc. All rights reserved.
Method D: Power Line Communication Bridges
(order EPLC-01 separately). This method requires
that you use the ferrite bead included with the IQ8D
Commercial Gateway.
Method E: Commercial Grade Wi-Fi Bridge.
Install a receptacle inside the enclosure if an Ethernet
over power line communication (PLC) bridge is
desired.
Install the enclosure in a location that is shaded from
direct sunlight. The IQ8D Commercial Gateway is rated
for ambient temperatures of -40°F to 115°F when
installed in an enclosure.
Do not drill holes on the top of the enclosure or
anywhere that allows moisture ingress if the enclosure
is outdoors. If top entry is needed, a water-tight conduit
hub, like a Myers HubTM or other suitable hub product
must be used.
Do not leave energized terminals or components easily
accessible and keep in a location that can be accessed
only by service personnel.
Consider drilling a small drain hole in the bottom,
lowermost corners of the enclosure box, so that
moisture or condensate can drain out of the enclosure.
IQ8D-DG-MKT-00397-02-EN-US-2022-06-10
33

Advertisement

Table of Contents
loading

Table of Contents