2.6 Lightning and surge suppression

Enphase microinverters have integral surge protection, greater than most traditional inverters.
However, if the surge has sufficient energy, the protection built into the microinverter can be
exceeded, and the equipment can be damaged. For this reason, Enphase recommends that you
protect your system with a lightning and/or surge suppression device. In addition to having some level
of surge suppression, it is also important to have insurance that protects against lightning and
electrical surges. Enphase has tested the following devices:
Leviton 51110-SRG
Schneider SquareD HEPD50
NOTE: Protection against lightning and resulting voltage surge must be in accordance
with local standards.

2.7 Parts and tools required

In addition to the microinverters, PV modules, and racking, you will need the following:

Enphase Equipment

IQ Gateway: Required to monitor production. IQ Gateway (model ENV-IQ-AM1-240)
communications gateway or IQ Combiner (model X-IQ-AM1-240-B, X-IQ-AM1-240-2, X-
IQ-AM1-240-3, X-IQ-AM1-240-3C).
Enphase Installer App: Download the Enphase Installer App, open it, and log in to
your Enphase account. Use it later to scan the microinverter serial numbers and
connect to the IQ Gateway to track system installation progress. To download, go
to
https://enphase.com/installers/apps
Tie wraps or IQ Cable Clips (Q-CLIP-100)
IQ Sealing Caps (Q-SEAL-10) for any unused drops on the IQ Cable
IQ Terminator (Q-TERM-10) typically two needed per branch circuit
IQ Disconnect Tool (Q-DISC-10)
IQ Field Wireable Connectors (male and female: Q-CONN-10M and Q-CONN-10F)
IQ Cable:
Cable model
Q-12-10-240
Q-12-17-240
Q-12-20-200

Other Items

AC junction box
Terminal screwdrivers
Wire cutters, voltmeter
Torque wrench, sockets, and wrenches for mounting hardware
14
IQ7/IQ7+/IQ7X/IQ7A Microinverters Installation and Operation Manual
Connector spacing
1.3 m
2.0 m
2.3 m
© 2023 Enphase Energy Inc. All rights reserved.
or scan the QR code.
PV module orientation
Portrait
Landscape (60-cell)
Landscape (72-cell)
Connector count
per box
240
240
200