● Ignoring Interval: The system does not produce
event log entries or issue remote notifications
regarding motion detected for the time specified
after the initial motion was detected. Set the value
between 1 sec and 5 secs or choose Never.
Ignoring Interval does not affect motion detection
recording.
● Daytime Setup: Specify when daytime starts and
ends. Adjust the time frame in 15-minute increments.
Times outside the specified range will be assumed as
nighttime by the system.

Video-Analytics_TripZone

● No.: Select which cameras to apply Trip Zone to.
● Sensitivity: Set daytime and nighttime sensitivity
settings between 1 (Low) and 5 (High).
● Zone: Define the motion detection block.
Use the remote control's arrow buttons to move the
block selection window up, down, left, and right. The
selection window consists of 8 blocks per row. Select/
deselect individual blocks using the Camera buttons.
You can use the mouse to drag the zone and then select,
clear, or reverse the selection.
From the zone selection screen, press the
on the remote control or right-click on the mouse to
open up the Zone Setup menu.
Part 2 - Configuration