24.1

Checking the starter motor

Condition
The starter motor has been removed.
-
Connect the negative cable of a 12 volt power supply to the
housing of the starter motor. Connect the positive cable of
the power supply briefly to connector
motor.
If the starter motor does not turn when the circuit is
closed:
-
Change the starter motor.
D00524-10

24 ELECTRIC STARTER

O
of the starter
..
273