Specify Ethernet/Ip Communication Settings - Panasonic LP-GS Series Operation Manual

Laser marker navi smart
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

24.17 Specify EtherNet/IP communication settings

If you are using the optional EtherNet/IP network unit, configure the communication settings.
EtherNet/IP communication is supported by LP-RF and LP-RV.
EtherNet/IP communication should be performed in a secure network environment.
For details about the EtherNet/IP configuration, refer to the "EtherNet/IP Communication
Guide".
1.
Establish an online connection between your PC and the laser marking system.
2.
Go to the "System settings" screen and select "Communication".
3.
Specify the EtherNet/IP communication settings.
ME-NAVIS2-OP-1
"DHCP":
Select "ON" (initial setting) to import the settings automatically for IP address, subnet
mask and default gateway from the DHCP server. If the network settings such as IP
address are not updated, check the connection status of the DHCP server.
Select "OFF" if you want to specify particular values for IP address, subnet mask and
default gateway.
Network settings
If "ON" is set for "DHCP", IP address, subnet mask and default gateway are
displayed.
If "OFF" is set for "DHCP", specify the values for IP address, subnet mask and
default gateway.
‒ "IP address": 0.0.0.0–223.255.255.255 (do not use 127 for the first octet)
Initial setting: 0.0.0.0
‒ "Subnet mask": 0.0.0.0–223.255.255.254
Initial setting: 0.0.0.0
Even if the value for the subnet mask is within the configurable range, it may be
invalid because of its combination.
‒ "Default gateway": 0.0.0.0–223.255.255.255 (do not use 127 for the first octet)
Initial setting: 0.0.0.0
‒ "MAC address": Displays the MAC address.
"Firmware version":
Displays the version of the installed EtherNet/IP network unit.
"LM → PLC data size (T → O) [byte]":
Displays the maximum data size that can be sent from your laser marking system to
your PLC.
460 bytes (fixed)
"PLC → LM data size (T → O) [byte]":
Displays the maximum data size that can be sent from your PLC to your laser
marking system.
320 bytes (fixed)
24 System settings
269

Advertisement

Table of Contents
loading

Table of Contents