Panasonic LP-GS Series Operation Manual page 334

Laser marker navi smart
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

27 Troubleshooting
E605, E606
Cause:
The combination of the version of Laser Marker NAVI smart and the
model or version of the laser marking system is not supported.
The function set with Laser Marker NAVI smart cannot be used with
this model of the laser marking system.
Remedy:
Use the right version of Laser Marker NAVI smart with the laser marking
system model in use.
E607
Cause:
The sensor signals are invalid. The line speed cannot be detected.
Remedy:
Make sure the first sensor in moving direction is connected to
ENCODER A IN (X13) and the second sensor is connected to
ENCODER B IN (X14) of the TERMINAL connector.
Turn on ENCODER B IN (X14) within 10s from the signal input at
ENCODER A IN (X13).
Input the signal at TRIGGER IN (X5) after turning on ENCODER B IN
(X14) within the set timeout period.
Applies to LP-RC, LP-RF, LP-RV only.
E608
Cause:
The counter value may not be updated because the laser marking
system was turned off during the marking process.
Remedy:
Check the current value of the counter.
Do not turn off the laser marking system during the marking.
E609
Cause:
The marking data could not be saved correctly because the laser
marking system was turned off during saving.
Remedy:
Check the file and the setting values.
Overwrite the file.
Do not turn off the laser marking system while saving a file.
334
ME-NAVIS2-OP-1

Advertisement

Table of Contents
loading

Table of Contents