Electrical Specifications

Description
Shipping carton length
Shipping carton width
Related Information
"Server Overview" on page 10
"Handling Precautions" on page 17
"Installing the Server" on page 25
"Electrical Specifications" on page 20
"Environmental Specifications" on page 21
"Airflow Precautions" on page 22
Electrical Specifications
Description
Voltage
Frequency
Maximum operating input current at 200 VAC (per
cord)
Maximum operating input power at 200 VAC
Maximum standby power
Maximum heat dissipation
The maximum operating input current values are based on P / (V *0.90), where P = max. operating input power, V= input voltage. Example:
620W / (120 * 0.90) = 6.89A You can use this equation to calculate your maximum operating current at your input voltage.
For information on power specifications, use the power calculator at:
http://www.oracle.com/us/products/servers-storage/sun-power-calculators
Related Information
"Powering On the Server for the First Time" on page 51
20
SPARC T8-1 Server Installation Guide • June 2019
U.S.
38.74 in.
23.62 in.
Value
Notes
200 to 240 VAC
50 to 60 Hz
5.7 A
Actual amperage draw may
exceed rating by no more than
10%.
1300W
20W
4456 BTU/hr
4702 KJ/hr
Metric
984 mm
600 mm