Electrical Specifications
"Handling Precautions" on page 22
■
"Installing the Server" on page 25
■
"Electrical Specifications" on page 16
■
"Environmental Specifications" on page 17
■
"Airflow Precautions" on page 18
■
Electrical Specifications
Description
Operating Input Range
Max Operating Input Current per cord at 100VAC
Max Operating Input Current per cord at 200VAC
Max operating input power at 100VAC
Max operating input power at 200VAC
Maximum heat dissipation
Maximum standby power
Maximum server configuration specification under nominal temperature and voltage conditions
(SPARC S7-2, Two 4.267GHz S7 Processors, 16 64GB DDR4 DIMMS, 4 SAS + 4 NVMe-SFF drives , 1 Internal HBA card, 3 PCIe cards)
Idle AC input power
Peak AC input power running MGRID
Minimum server configuration specification under nominal temperature and voltage conditions
(SPARC S7-2-1S, One 4.267GHz S7 Processors, 4 16GB DDR4 DIMMS, 0 drives, 1 Internal HBA card, 0 PCIe cards)
Idle AC input power
Peak AC input power running MGRID
For information on power specifications, use the power calculator at:
http://www.oracle.com/us/products/servers-storage/sun-power-calculators
Related Information
"Powering On the Server for the First Time" on page 57
■
16
SPARC S7-2 Server Installation Guide • July 2016
Value
100 to 120 VAC; 200 to 240 VAC; 50-60 Hz
8.6 A
4.1 A
851 W
819 W
2904 BTU/hr
3064 KJ/hr
23.4 W
412 W
749 W
190 W
352 W