"Physical Specifications" on page 19
■
"Environmental Specifications" on page 21
■
"Airflow Precautions" on page 22
■
Environmental Specifications
This topic includes these specifications that apply to both server configurations:
Temperature, humidity, and elevation
■
Shock and vibration
■
Acoustic
■
TABLE 1
Temperature, Humidity, and Elevation Specifications
Description
Operating
U.S.
Temperature
41 to 95°F at 0 to
(maximum)
3000 ft
Relative humidity
10 to 80% at 81°F
Altitude
0 to 9840 ft
at 95°F
†
Except in China markets where regulations might limit installations to a maximum altitude of 2km.
TABLE 2
Description
Shock
Vibration (vertical)
Vibration (horizontal)
TABLE 3
Description
Sound Power Level - LwAd (1 B=10 dB)
Sound Pressure Level - LpAm (energy
average of four bystander positions)
Metric
5 to 35°C at
900m
10 to 80% at
27°C
0 m to 3000m at
†
40°C
†
Shock and Vibration Specifications
Operating
3G, 11 ms
0.15G
0.10G
Acoustic Specifications
Nonoperating
U.S.
Metric
-40 to 149°F at 0
-40 to 65°C at
to 3000 ft
900m
Up to 85% at
Up to 85% at
100°F
38°C
Up to 39,370 ft
Up to 12,000m
Notes
Half-sine
5 to 500 HZ swept-sine
Operating at 60%
8.2 B
66.2 dBA
Environmental Specifications
Notes
Decrease in maximum temperature:
above 3000 ft. (900m), 1.8°F/1000 ft
(1°C/300m)
Maximum wet bulb noncondensing
Operating at 100%
9.7 B
80.3 dBA
Specifications
21
Need help?
Do you have a question about the SPARC T8-1 and is the answer not in the manual?
Questions and answers