Errors And Error Types; Table 35: Errors And Error Types - WAGO 750 Manual

4fdi 24v profisafe
Table of Contents

Advertisement

84
Diagnostics
8.2

Errors and Error Types

Table 35: Errors and Error Types

Error
Safe Inputs
Internal channel error
Short circuit
Overload clock output
Discrepancy time exceeded
General
Safety shutdown (internal error)
Firmware update required
Invalid iParameters
Overtemperature error
Undervoltage field supply
Overvoltage field supply
Overtemperature warning
F_Dest_Add mismatch
Invalid F_Dest_Add
Invalid F_Source_Add
Invalid F_WD_Time
Non-supported F_SIL
Incorrect F_CRC_Length
Incorrect F_Par_Version
Invalid F_CRC1
Inconsistent F_iPar_CRC
Non-supported F_Block_ID
Invalid F parameters
Error uploading iParameters
Error downloading iParameters
PROFIsafe CRC2 error
F_WD_Time expired
Acknowledgement required
Manual
Version 1.0.0, valid from HW/SW Version 01/01
WAGO I/O System 750
753-661/000-004 4FDI 24V PROFIsafe
Error Type
Channel error
Channel error
Channel error
Channel pair error
Module error
Module error
Module error
Module error
Module error
Module error
Module error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Configuration error
Communication error
Communication error
Coding
0x0280
0x0201
0x0286
0x021E
0x0219
0x0231
0x0200
0x0205
0x0202
0x0230
0x0232
0x0040
0x0041
0x0042
0x0043
0x0044
0x0045
0x0046
0x0047
0x004B
0x004C
0x0048
0x0049
0x004A
0x004D
0x004E
0x004F

Advertisement