1523.5-0000010 OM

2.20.4 Fuses for engine electronic control system

The installation place of the fuse for the EECS constant supply (at any position of the AB
switch) with rated value of 60A is shown in fig. 2.20.7.
To get an access to the rest of the EECS cutout fuses, turn off screw 3 (figure 2.20.14) on
cap 2 of side console 1 and open the cap. The EECS block fuse is fixed to the element of
the cab housing.
1 – side console; 2 – cap; 3 – screw; 4 – EECS block fuse.
Figure 2.20.14 – The location of EECS fuses
The EECS fuses are shown in figure 2.20.15.
1 – block fuse; 2 – power fuse of the engine electronic control box; 3, 4 – duplicate fuse; 5
– power fuse of the reagent AdBlue hose pipe heaters (discharge, drain, intake) and of
SCR system feeding module heater.
Figure 2.20.15 – EECS fuses