Timer Class For Trunks - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Level:
IN
Description
Use Program 20-30 : Timer Class for Trunks to assign the timer class to each trunk.
There are 16 Classes that can be assigned. You make eight entries for this Program,
one for each Night Service Mode. The details of classes are assigned by PRG 20-3.
Input Data
Item
No.
01
Day/Night Mode 1~8, Class Number
Feature Cross Reference
None
Electra Elite IPK II Programming Manual
Program 20 : System Option Setup
Item
Conditions
None

20-30 : Timer Class for Trunks

Input Data
0~15, #,
,
0 = Not assigned
Document Revision 1
Related
Default
Programming
0