Document Revision 1
Level:
IN
Description
Use Program 20-31 : Timer Class Timer Assignment to assign values to the timers
on a class of service basis.
Input Data
Item
No.
01
Trunk Queuing Callback Duration Time
02
Callback / Trunk Queuing Cancel Time
03
CAR/SIE/Virtual Extension Delay Interval
04
Intercom Inter-digits Time (Intercom I/D
Timer)
05
Trunk Inter-digits Time (Trunk I/D Timer)
06
Hotline Time Start Time (Hotline Start)
07
Ring No Answer Alarm Time
08
DIL/Incoming Ring Group No Answer Time
DID Ring-No-Answer Time
09
10
Hold Recall Time (Non Exclusive Hold)
11
Hold Recall CallBack Time (Non Exclusive
Hold)
Exclusive Hold Recall Time
12
13
Exclusive Hold Recall Callback Time
14
Park Hold Time – Normal
15
Delayed Call Forwarding Time (Call Forward
No Answer)
16
Transfer Recall Time
17
DID/DISA No Answer Time (Disconnect or
IRG or VM)
Disconnect after Re-transfer to IRG
18
2 - 198
Program 20 : System Option Setup
20-31 : Timer Class Timer Assignment
Item
Input Data
0~64800 seconds
0~64800 seconds
64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
0~64800 seconds
Program 20 : System Option Setup
Electra Elite IPK II
Related
Default
Programming
15 seconds
20-01-08
20-01-09
10 seconds
20-04-03
10 seconds
21-01-02
5 seconds
21-01-03
5 seconds
21-01-09
60 seconds
22-01-02
0 seconds
22-01-04
20 seconds
22-01-06
90 seconds
24-01-01
30 seconds
24-01-02
90 seconds
24-01-03
30 seconds
24-01-04
90 seconds
24-01-06
10 seconds
24-02-03
30 seconds
24-02-04
30 seconds
25-07-02
60 seconds
25-07-03