Vrs Delay Announcement - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Level:
SA
Description
Use
be used as the message source for the 1st and 2nd Delay Announcement Messages.
Turn to Program 41-08 for more on setting up the ACD overflow options.
This program is activated when the delay announcement source and options are
assigned as VRS in Program 41-08.
Input Data
Electra Elite IPK II Programming Manual
Program 41-11 : VRS Delay Announcement
ACD Group No.
Item
No.
01
Delay Message Start Timer
02
1st Delay Message Number
03
1st Delay Message Sending Count
04
2nd Delay Message Number
05
2nd Waiting Message Sending Count
06
Tone Kind at Message Interval
07
ACD Forced Disconnect Time After the
After 2nd Delay Message
08
Queue Depth Announcement
(Requires VRS)
Program 41 : ACD Setup

41-11 : VRS Delay Announcement

to assign the VRS message number to
Item
0 = No Message
49 = Fixed Message
0 = No Message
49 = Fixed Message
0 = Ring Back Tone
1 = MOH Tone
2 = BGM Source
3 = After 1st and 2nd
Document Revision 1
01~64
Input Data
Default
0~64800 (sec)
0~49
0~255
0~49
0~255
0~64800 (sec)
0 = Disable
1 = After 1st (1st)
2 = After 2nd (2nd)
(1st and 2nd)
0
0
0
0
0
0
60
0
2 - 373