Table 2-2 System Numbering Default Settings - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 1
Step 2: Specify the length of the code you want to change
After you specify a single or two digit code, you must tell the system how many digits
comprise the code. This is the Number of Digits Required column in the
System Numbering Default Settings on page 2-33
codes from 100-999 are three digits long. Codes beginning with 0 are one digit long.
Codes beginning with
Step 3: Assign a function to the code selected
After entering a code and specifying its length, you must assign its function. This is
the Dial Type column in the
2-33
Dial
Types
Changing the Dial Type for a range of codes can have a dramatic affect on how your system
operates. Assume, for example, the site is a hotel that has room numbers from 100-399. In order
to make extension numbers correspond to room numbers, you should use Program 11-02 to
reassign extension numbers on each floor from 100 to 399. (Other applications might also
require you to change entries in Program 11-10 through 11-16.)
2 - 32
the other codes are single digit. If you enter a two digit code between 0 and 9, be
sure to make separate entries for all the other two digit codes within the range as
well. This is because in the default program all the two digit codes between 0 and 9
are undefined.
are 3 digits long and codes beginning with # are 4 digits long.
,
table. The choices are:
Dial Type Description
0
--- Not Used ---
1
Service Code
2
Extension Number
3
Trunk Access Code
4
Special Trunk Access
5
Operator Access
6
ARS/F-Route Access
Table 2-2 System Numbering Default Settings on page
11-10 : Service Code Setup (for System Administrator)
11-11 : Service Code Setup (for Registration)
11-12 : Service Code Setup (for Service Access)
11-13 : Service Code Setup (for ACD)
11-14 : Service Code Setup (for HOTEL)
11-15 : Service Code Setup (Special access)
11-16 : Service Code Setup (Single Digit)
11-02 : Extension Numbers
11-04 : Virtual Extension Numbers
11-06 : PGD(2)-U10 (ACI) Extension Numbers
11-07 : Department Calling Group Numbers
11-08 : PGD(2)-U10 (ACI) Group Pilot Numbers
11-09 : Trunk Access Code
11-09 : Trunk Access Code
20-17 : Operator's Extension
44-xx
Electra Elite IPK II
table. In the default program, all
Related Program
Program 11 : System Numbering
Table 2-2

Hide quick links:

Advertisement

Table of Contents
loading