NEC Electra Elite IPK II Programming Manual page 190

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Input Data
Item
No.
04
05
06
07
Feature Cross Reference
J
J
Electra Elite IPK II Programming Manual
Item
Dial Sending Start Time for SLT or ARS
When ARS or an analog extension user
accesses a trunk and dials an outside call, the
system waits this interval before outdialing the
first digit.
When using a third-party external paging
device, set this option to 1. In addition, set
Program 20-03-03 to 1.
SLT Operation Mode
Headset Ringing Start Time
Define the headset ringing start time. After this
timer expires from the time when a single line
telephone is off-hook, the system will set the
single line telephone to headset ringing mode.
Trunk call dial forced sending start time
(Forced Dial)
Conditions
None
Single Line Telephones, Analog
Single Line Telephones, Digital
Document Revision 1
Input Data
Default
0~64800 seconds
0
= Normal
Mode
1
= Extended
Mode1
2
= Extended
Mode2
0~64800 seconds
0~64800 seconds
Related
Program
3
20-03-03
0
5
20-13-38
0
20-03-03
20-03-04
2 - 155