Description
Use Program 21-09 : Dial Block Setup to define the Dial Blocking Toll Restriction
Class and Dial Block Password to be used by the Supervisor extension.
Input Data
Item
No.
01
02
Feature Cross Reference
J
Electra Elite IPK II Programming Manual
Program 21 : Outgoing Call Setup
Toll Restriction Class With Dial Block
Assign a Toll Restriction Class of Service when the Dial Block
feature is used.
Supervisor Password
Assign a 4-digit password to be used by the supervisor to enable
or disable Dial Block for other extensions.
Conditions
This function works by password and Class of Service control (the supervisor is
H
not an assigned extension). If Dial Block is available for all Classes of Service,
everyone may become a supervisor if they know the Dial Block password.
Toll Restriction

21-09 : Dial Block Setup

Item
Document Revision 1
Input Data
Default
1~15
15
0~9,
, #
No
,
(4-digit fixed)
Setting