Call Progress Tone Detector Setup - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 1
Program 80 : Basic Hardware Setup for System
Level:
IN
Description
Use
and timers for the Call Progress Tone Detector.
Tone Detector Type:
J
J
J
J
Input Data
Item No
04
No tone time
05
Pulse Count
06
ON min. time
07
ON max. time
08
OFF min. time
09
OFF max. time
10
--- Reserve ---
11
--- Reserve ---
2 - 488

80-04 : Call Progress Tone Detector Setup

Program 80-04 : Call Progress Tone Detector Setup
1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4, 5 = Reserved
Tone Detector Type No.
Item
to define the various levels
1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = --- Reserve ---
5 = --- Reserve ---
Input Data
0~255 (30+30-7680ms)
1~255
1~255 (30+30-7680ms)
0~255 (30+30-7680ms)
1~255 (30+30-7680ms)
0~255 (30+30-7680ms)
0~8
0~8
Program 80 : Basic Hardware Setup for System
Electra Elite IPK II

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents