Digital I/O (I/O) - MICRO-EPSILON colorSENSOR CFO Operating Instructions Manual

Table of Contents

Advertisement

Installation and Assembly
4.3.3
The five push-pull switching outputs on the 8-pin connector I/O 1 are electrically connected to the power sup-
ply. The switching output logic level depends on the supply voltage V
Use:
- Direct for a total of 8 individual colors or binary for 254 color groups.
The switching state zero is not used to ensure reliable test performance in the face of a discontinuity.
The switching state all switched is recommended as the standard error output.
The cable shield is connected to the housing.
All GND conductors are interconnected with one another and to the supply voltage ground.
Micro-Epsilon recommends the optionally available CAB-M12-8P-St-ge
Pin
1
2
3
4
5
6
7
8
Fig. 14 I/O Digital I/O Connector
The color outputs can be programmed using the keypad.
1) Applies only for colorSENSOR CFO200.
2) Conductor color CAB-M12-8P-St-ge
colorSENSOR CFO

Digital I/O (I/O)

Connect the cable shield to the evaluation unit.
Use a shielded cable with a length < 30 m.
Color
Function Description
2
IN1
Trigger input
White
Brown
IN2
Trigger input
Green
IN3
Trigger input
Yellow
OUT3
Switching output (NPN/PNP/PP)
Gray
OUT4
Switching output (NPN/PNP/PP)
Pink
OUT5
Switching output (NPN/PNP/PP)
Blue
OUT6
Switching output (NPN/PNP/PP)
Red
OUT7
Switching output (NPN/PNP/PP)
connected.
+
cable, see A
1.
2
1
7
View of control-
Pin sequence, 8-pin
ler
cable connector,
flange socket
view of solder side
3
4
8
5
6
Page 31