5.3.7.2
Extending the hold time of a detection result beyond the actual duration of the color match is useful if the ac-
tuators controlled by the color measuring system require a certain minimum hold time of the switching level
or the measurement is faster than the reaction time of the downstream evaluation unit.
The hold time can be set to one of three different stages in the option menu.
Stage
1
2
3
colorSENSOR CFO
Hold Time
Hold Time
Description of LED display
0 ms
1x flashing with 150 / 150 ms, followed by 900 ms off = 1200 ms
10 ms
2x flashing with 150 / 150 ms, followed by 600 ms off = 1200 ms
1000 ms
3x flashing with 150 / 150 ms, followed by 300 ms off = 1200 ms
TEACH
INT
AUTO
CLR
OPT
GATE
1
TEACH
2
HOLD
3
ESC
MULTI
4
TOL
CLASSIFY
5
SPHERE
6
CYLINDER
7
8
BOX
INT
TEACH
AUTO
The activated hold time is signaled by the associated LED flashing.
CLR
OPT
1
GATE
TEACH
2
HOLD
3
ESC
MULTI
4
TOL
CLASSIFY
5
SPHERE
6
7
CYLINDER
BOX
8
Press the
key for less than 2 sec. to select the option group.
Press the TEACH key for less than 2 sec. to activate the hold time for all
outputs.