Ricoh IM C300 Service Manual page 1571

Table of Contents

Advertisement

0
0
Other settings - Not used
IP Fax Switch 07 (SP No. 1-111-008)
No. Function
0
TSI information
0: Not added, 1: Added
1
DCN transmission setting at T1 timeout
0: Not transmitted
1: Transmitted
2
Not used
3
Hang up setting at DIS reception disabled
0: No hang up
1: Hang up after transmitting DCN
4
Number of times for training
0: 1 time, 1: 2 times
5
Space CSI transmission setting at no CSI
registration
0: Not transmitted
1: Transmitted
6-7
Not used
IP Fax Switch 08 (SP No. 1-111-009)
No. Function
0-1
T1 timer adjustment
Bit 1
Bit 0
0
0
0
1
1
0
1
1
2-3
T4 timer adjustment
Bit 3
Bit 2
0
0
0
1
1
0
1
1
4-5
T0 timer adjustment
D0CK
0
1
1
0
Comments
Adjusts the T1 timer.
The default is "00" (35 seconds).
35s
40s
50s
60s
Adjust the T4 timer.
The default is "00" (3 seconds).
3s
3.5s
4s
5s
Adjusts the fail-safe timer. This timer sets the interval between "setup"
1
V.27ter, V.29, V.33
0
V.27ter, V.29, V.17/V.33
Comments
Adds or does not add TSI information to NSS(S).
Transmits or does not transmit DCN at T1 timeout.
Do not change this setting.
Sets whether the machine disconnects after DIS
reception.
Selects the number of times training is done at the
same bit rate.
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is all
spaces.
Do not change these settings.
96
Bit Switches – 5
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Im c300fIm c400fIm c300srfD0caD0c9D0c8 ... Show all

Table of Contents