Error Codes
Code
substitute RX or confidential RX
message
5-25
SAF file access error
6-00
G3 ECM - T1 time out during
reception of facsimile data
6-01
G3 ECM - no V.21 signal was
received
6-02
G3 ECM - EOR was received
6-04
G3 ECM - RTC not detected
6-05
G3 ECM - facsimile data frame not
received within 18s of CFR, but there
was no line fail
6-06
G3 ECM - coding/decoding error
6-08
G3 ECM - PIP/PIN received in reply to
PPS.NULL
6-09
G3 ECM - ERR received
6-10
G3 ECM - error frames still received
at the other end after all
communication attempts at 2400 bps
6-21
V.21 flag detected during high speed
modem communication
6-22
The machine resets the sequence
SM
Meaning
Suggested Cause/Action
•
Ask the other end to resend the message.
•
Replace an SD card or HDD.
•
Replace the FCU (PCB2).
•
Try adjusting the RX cable equalizer.
•
Replace the FCU (PCB2).
•
Check the line connection.
•
Check for a bad line or defective remote
terminal.
•
Replace the FCU (PCB2).
•
Check the line connection.
•
Check for a bad line or defective remote
terminal.
•
Replace the FCU (PCB2).
•
Try adjusting the RX cable equalizer
Cross reference
•
RX cable equalizer - G3 Switch 07 (PSTN)
•
Defective FCU (PCB2).
•
The other terminal may be defective.
•
The other end pressed Stop during
communication.
•
The other terminal may be defective.
•
Check for a noisy line.
•
Adjust the TX levels of the communicating
machines.
•
See code 6-05.
•
Check for line noise.
•
Adjust the TX level (use NCU parameter 01 or
the dedicated TX parameter for that address).
•
Check the line connection.
•
Defective remote terminal.
•
The other terminal may be defective or
incompatible.
•
Check for line noise.
27
D0CK