Code
2-22
Counter overflow error of JBIG chip
2-23
JBIG compression or reconstruction
error
2-24
JBIG ASIC error
2-25
JBIG data reconstruction error (BIH
error)
2-26
JBIG data reconstruction error (Float
marker error)
2-27
JBIG data reconstruction error (End
marker error)
2-28
JBIG data reconstruction error
(Timeout)
2-29
JBIG trailing edge maker error
2-50
The machine resets itself for a fatal
FCU (PCB2) system error
2-51
The machine resets itself because of
a fatal communication error
2-53
Snd msg() in the manual task is an
error because the mailbox for the
operation task is full.
4-01
Line current was cut
4-10
Communication failed because of an
ID Code mismatch (Closed Network)
or Tel. No./CSI mismatch (Protection
against Wrong Connections)
5-00
Data reconstruction not possible
5-10
DCR timer expired
5-20
Storage impossible because of a lack
of memory
5-21
Memory overflow
5-23
Print data error when printing a
D0CK
Meaning
Suggested Cause/Action
•
Replace the FCU (PCB2).
•
If this error occurs frequently, change the
settings for resolution, paper size and
compression type.
•
Turn off the machine, then turn it back on.
•
Turn off the machine, then turn it back on.
•
JBIG data error
•
Check the sender's JBIG function.
•
Update the MBU ROM.
•
FCU (PCB2) defective
•
Check the destination device.
•
If this is frequent, update the ROM, or replace
the FCU (PCB2).
•
If this is frequent, update the ROM, or replace
the FCU (PCB2).
•
The user did the same operation many times,
and this gave too much load to the machine.
•
Check the line connector.
•
Check for line problems.
•
Replace the FCU (PCB2).
•
Get the ID Codes the same and/or the CSI's
programmed correctly, then resend.
•
The machine at the other end may be defective.
•
Replace the FCU (PCB2)
•
Replace the FCU (PCB2).
•
Temporary memory shortage.
•
Test the SAF memory.
•
Test the SAF memory.
26