Ricoh IM C300 Service Manual page 1497

Table of Contents

Advertisement

Code
0-15
The other terminal is not capable of
specific functions.
0-16
CFR or FTT not detected after modem
training in confidential or transfer
mode
0-17
Communication was interrupted by
pressing the stop key
0-20
Facsimile data not received within 6 s
of retraining
0-21
EOL signal (end-of-line) from the
other end not received within 5 s of
the previous EOL signal
D0CK
Meaning
Suggested Cause/Action
Noisy line: resend.
Try adjusting the TX level and/or cable
equalizer settings.
Replace the FCU (PCB2).
Cross reference
See error code 0-08.
The other terminal is not capable of accepting the
following functions, or the other terminal's memory
is full.
Confidential RX
Transfer function
SEP/SUB/PWD/SID
Check the line connection.
Replace the FCU (PCB2).
Try adjusting the TX level and/or cable
equalizer settings.
The other end may have disconnected, or it
may be defective; try calling another machine.
If the RX signal level is too low, there may be a
line problem.
Cross reference
See error code 0-08.
If the Stop key was not pressed and this error
keeps occurring, replace the operation panel or
the operation panel drive board.
Check the line connection.
Replace the FCU (PCB2).
Check for line problems.
Try calling another fax machine.
Try adjusting the reconstruction time for the first
line and/or RX cable equalizer setting.
Cross reference
Reconstruction time - G3 Switch 0A, bit 6
RX cable equalizer - G3 Switch 07 (PSTN)
Check the connections between the FCU
(PCB2) and line.
Check for line noise or other line problems.
Replace the FCU (PCB2).
22
Error Codes
SM