OVERVIEW OF THE COMbIVERT F6
Housing 2
9
7
11
6
6a
Figure 15:
F6 housing 2 front view
52
8
10
5
Terminal R can alternatively be labeled with PB.
No.
Name
Power circuit terminals for:
•
Mains input
5
X1A
•
Braking resistor
•
DC supply
•
Motor connection
Protective earth;
when connecting the protective earth,
6
PE
each terminal may be assigned only
once.
Fixing points for the optional shielding
plates. The shielding e.g. from the
motor cable is laid on the mounting
plate in the control cabinet or on the
shielding plates (optionally available).
6a
---
Power unit:
•
Built-in version
00F6V80-2001
•
Push-through version
00F6V80-2002
7
X3A
Encoder interface channel A
8
X3B
Encoder interface channel B
Terminal for:
9
X1C
•
Motor temperature monitoring
•
Brake control
10
---
Interior fan
11
---
Heat sink fan
Description