Troubleshooting
Fault description
The "Stroke length adjustment" symbol
appears flashing on the LCD screen, plus
'Stroke length adjusted'
the error message
5.
The "Overload" p+ symbol appears
flashing on the LCD screen plus the error
'Overload ' 6.
message
The "Temperature" symbol
flashing on the LCD screen, plus the error
'Temperature FC' 7.
message
The "Temperature" symbol
flashing on the LCD screen, plus the error
'Temperature PFC' 7.
message
'BUS' symbol appears flashing on
The
the LCD screen, plus the error message
'CANopen pump' 8.
14.5
All other faults
14.6
Log book
78
Cause
The stroke adjustment
dial was rotated by more
than 10% while the
menu was locked.
A constriction or a
closed shut-off valve on
the pressure side.
appears
The frequency converter
C
F
is overloaded.
The temperature is too
high.
appears
The pump is over‐
C
F
loaded.
The temperature is too
high.
The HMI was connected
to a CANopen pump.
Please contact the responsible ProMinent subsidiary or representative -
see www.prominent.com - "Contact" - "Your contacts worldwide" or pos‐
sibly the Legal Notices in these operating instructions.
Tab. 11: Input information
Line
1
2
3
4
5
Remedy
Turn the stroke adjustment
dial back or enter the code.
Open the shut-off valve or
rectify the constriction.
Rectify the cause, then
[P/OK] (think through
Press
the consequences for the
process!).
Rectify the cause, then
[P/OK] (think through
Press
the consequences for the
process!).
Rectify the cause, then
[P/OK] (think through
Press
the consequences for the
process!).
Rectify the cause, then
[P/OK] (think through
Press
the consequences for the
process!).
Disconnect the HMI from the
pump.
Information
Line number
Date/time
Type of entry (fault, warning ...)
Input number
Explanation of the input
Personnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel