Fault description
The p+ "Overload" symbol appears
flashing on the LCD screen plus the error
'Overload' 6.
message
The "Temperature" symbol
flashing on the LCD screen, plus the error
'Temperature FC' 7.
message
The "Temperature" symbol
flashing on the LCD screen, plus the error
'Temperature PFC' 7.
message
The
'BUS' symbol appears flashing on
the LCD screen, plus the error message
'CANopen pump' 8.
14.4
All other faults
14.5
Log book
14.5.1
Warning messages in the log book
Tab. 10
No.
Description
1
Float switch input reports feed chemical nearing an end
2
Calibration warning: Appears if the stroke length is adjusted above the tolerance and the pump
therefore has to be recalibrated
Cause
A constriction or a
closed shut-off valve on
the discharge side.
appears
The frequency converter
C
F
is overloaded.
The temperature is too
high.
appears
The pump is over‐
C
F
loaded.
The temperature is too
high.
The HMI was connected
to a CANopen pump.
Please contact the responsible ProMinent branch or representative - see
www.prominent.com - "Contact" - "Your contacts worldwide" or possibly
the Legal Notices in these operating instructions.
Tab. 9: Input information
Line
1
2
3
4
5
Remedy
Open the shut-off valve or
rectify the constriction.
Rectify the cause, then
[P/OK] (think through
Press
the consequences for the
process!).
Rectify the cause, then
[P/OK] (think through
Press
the consequences for the
process!).
Rectify the cause, then
Press
[P/OK] (think through
the consequences for the
process!).
Rectify the cause, then
[P/OK] (think through
Press
the consequences for the
process!).
Disconnect the HMI from the
pump.
Information
Line number
Date/time
Type of entry (fault, warning ...)
Input number
Explanation of the input
Troubleshooting
Personnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
Technical per‐
sonnel
81