ProMinent Sigma X Operating Instructions Manual page 36

Diaphragm motor-driven metering pump
Hide thumbs Also See for Sigma X:
Table of Contents

Advertisement

Installation
7.2.2.2
External control
Function "External Contact"
(ProMinent external/contact cable)
2-core
Function "External Contact"
(ProMinent universal control wire)
5-core
"Pause" function
"Auxiliary rate" function
Function "External Contact"
Technical data "External control"
36
Universal control wire connection diagram
Universal control wire connection diagram
Site end
Site end
2 white / Contact
4 brown / GND
Pulse frequency,
e.g. contact water meter, PLC etc.
3 blue / Analog
2 white / Contact
1 brown / Pause
4 black / GND
5 grey /Auxiliary
Pulse frequency,
e.g. contact water meter, PLC etc.
3 blue / Analog
2 white / Contact
1 brown / Pause
4 black / GND
5 grey /Auxiliary
Continuous contact (potential-free)
E.g. external on/off of control panel
3 blue / Analog
2 white / Contact
1 brown / Pause
4 black / GND
5 grey /Auxiliary
Continuous contact (potential-free)
e.g. of control panel
3 blue / Analog
+
2 white / Contact
0/4-20 mA
1 brown / Pause
-
4 black / GND
5 grey /Auxiliary
Analog signal,
e.g. of magnetic inductive
Flow meter
Semi-conductor switch elements with a residual voltage of –0.7 V (e.g.
transistors in open-collector circuits) or contacts (relays) can be used as
input switch elements.
Pump, inside
Pump, inside
Cable
Cable
External
activation
External
activation
External
activation
External
activation
External
activation
P_SI_0091_SW
GND
GND
GND
GND
GND