Options; Function And Fault Indicator; Lcd Screen; Led Displays - ProMinent Sigma X Operating Instructions Manual

Diaphragm motor-driven metering pump
Hide thumbs Also See for Sigma X:
Table of Contents

Advertisement

"Priming" function

5.7 Options

Relay option
"0/4-20 mA analogue current output and
fault indicating relay" option

5.8 Function and fault indicator

5.8.1 LCD screen

5.8.2 LED displays

Pump device LEDs
Fault indicator (red)
The following functions are triggered by pressing a key:
"Stop" function: the pump can be stopped without disconnecting it from the
mains/power supply by pressing
Priming can be triggered by pressing
The pump has several connection possibilities for the following options:
"Output relay" option: In the event of fault signals, warning signals, stop‐
ping of the pump or tripped level switches, the relay connects to complete
an electric circuit (for alarm horns etc.).
The relay can be retrofitted via a knock-out in the drive unit.
The various functions can be adjusted – see "Settings" - "Relays" chap‐
ters.
"Fault indicating relay and semiconductor relay" option: In the event of
fault signals, warning signals, stopping of the pump or tripped level
switches, the fault indicating relay connects to complete an electric circuit
(for control panel etc.).
In addition to the fault indicating relay, the pacing relay can be used to
make a contact every stroke.
Other functions can be adjusted – see "Settings" - "Relays" chapters. The
option can be retrofitted via a knock-out in the drive unit.
The current output I signal indicates the pump's actual calculated metering
volume.
The "0/4-20 mA analogue current output and fault indicating relay" option
can be retrofitted via a knock-out in the control unit.
The option also always includes a semiconductor relay - see above. Other
functions can be adjusted – see "Settings" - "Relays" chapters.
The operating and fault statuses are indicated by the 3 or 4 LED displays
'Error' identifier on the LCD screen:
and the
If a fault occurs, the identifier
sage – see "Troubleshooting" chapter
- see "Troubleshooting" chapter
The fault indicator lights up if the fluid level in the dosing tank falls below
the second switching point of the level switch (20 mm residual filling level
in the dosing tank).
Functional description
[STOP/START] .
[Priming] .
'Error' appears with an additional error mes‐
23